<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>val</ParameterFamily>
<LongName>
picker_ss_release_position
</LongName>
<Name>
psrp
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This value (in millimeters) is used to determine when the picker releases the
slipsheet to hand it off to to the slipsheet rollers.  The picker first moves
till the wedgemaster is in the center of the open rollers, then lowers the
wedgemaster, then drags the slipsheet between the 'bat wings to
picker_ss_release_position, where it releases the slipsheet and closes the
rollers.
</text></DescriptionText>
</Description>
<Type>
uint32
</Type>
<Default>
<UnnumberedList>
<li>150</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>50 to 350</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:48 2008 PST